Wired Starts

A start signal is considered a wired start when it is received by FinishLynx via the Start port in the Connection Box. It can be produced by the sound of a gun, an electronic start system or a tape switch, for example.

Start sensor

To receive a wired start, the correct type of Start Sensor must be selected.

  • To select the start sensor:
  1. Access the Camera Settings of a timer-enabled EtherLynx camera.
  2. Click on the Inputs Tab.
  3. Click the radio button to select the type of start sensor (Open or Closed) used.
  4. Click Ok.

note: The standard FinishLynx start sensor is Normally Closed (see label on start sensor to confirm).

tip: The Lynx Electronic Start System requires Normally Open.

How to create a wired start?

  • To do this:
  1. Create a new Event.
  2. Start the race (fire gun, depress tape-switch, etc...).
  • When the start sensor detects a signal:
  1. A start time is added to the Start Listing
  2. A start line is added in the Information Zone with the start time.
  3. The Armed indicators are removed.
  4. The Running Time box displays the running time.

What's next?

After configuring the start sensor, go to Arming, Re-Arming & Disarming.