Sending data to a scoreboard
LynxPad can send information to practically any commercially available scoreboard. If you want to send information to a scoreboard that is not currently supported, please contact our technical support staff (see "Contacting Lynx System Developers, Inc.").
LynxPad can be configured to send the following information to a scoreboard display:
- start lists
- information about competitors involved in the event in progress
- results from a previous event, or
- team scores (as long as your scoreboard supports this).
note: You can also send Results and Team Scores simultaneously for display on two separate scoreboards.
Connecting LynxPad to a scoreboard
There are many ways to connect LynxPad to a scoreboard, including:
- directly to the LynxPad through the computer's COM port (note: if your computer does not have a spare COM port, you can either purchase a button splitter from Lynx or contact Lynx to explore other options)
- through the C-Box using the DB9 serial port
- over a TCP/IP network, or
- through UDP communication.
If you need help with connecting LynxPad to a scoreboard, contact Lynx System Developers, Inc (see "Contacting Lynx System Developers, Inc.").
Configuring LynxPad for scoreboard use
Step 1: Activate the Scoreboard | Options dialog
- Click Scoreboard | Options from the Menu bar. The Scoreboard Options dialog appears.
- Click New. The functions on the Options dialog activate.
Step 2: Find your scoreboard in the Scoreboard Settings table
Refer to the Scoreboard Settings table below. Locate the scoreboard that LynxPad will send data to and then note the corresponding script and data settings.
note: A "Yes" in the Team Scores Display column means Lynx has tested the corresponding scoreboard and confirmed that it will display Team Scores. "Untested" means that we have not been able to confirm if it will or will not display Team Scores. If you conduct your own testing, Lynx (mailto:support@finishlynx.com) would appreciate hearing your results.
| MANUFACTURER | MODEL | SCRIPT | SETTING | TEAM SCORE |
|---|---|---|---|---|
| DISPLAY | ||||
| Alge | GAZc | Alge.lss | 2400,8,N,1 | Untested |
| Daktronics | V6400/ 6000 Omnisport Allsport | Dak.lss Allsport.lss | 9600,8,N,1 9600,7,E,2 12800,8,N,2 | Untested |
| Untested | ||||
| Yes | ||||
| Chronomix | CC2000 | Chrono.lss | 9600,8,N,1 | No |
| Colorado Time | CT4009 | Colorado.lss | 9600,8,E,1 | Untested |
|---|---|---|---|---|
| Fairtron | n/a | Fairtron.lss | 9600,8,N,1 | Untested |
| Electro Numerics | RaceClocks | Electro.lss Electro-flip.lss Electro-led.lss Electro2.lss | 9600,8,N,1 1200,8,E,1 9600,8,N,1 9600,8,Mark,2 | Untested |
| Untested | ||||
| Untested | ||||
| Untested | ||||
| IDS | ECMX | 9600,8,N,1 | Untested | |
| Lynx | LynxTV ResulTV | Lynxtv.lss Resultv220.lss | 9600,8,N,1 9600,8,N,1 | Untested |
| Yes | ||||
| Microgate | Mtab16 Mtab16 µGraph | Microtab 16- 9.lss Microtab 16- 18.lss uGraph.lss | 1200,8,N,1 1200,8,N,1 9600,8,N,1 | Yes |
| Yes | ||||
| Yes | ||||
| Nevco | Nevco1.lss Nevco2.lss Nevco123.lss Nevco860.lss | 38400,8,N,1 38400,8,N,1 57600,8,N,1 57600,8,N,1 | Untested | |
| Untested | ||||
| Untested | ||||
| Untested | ||||
| Omega | UNT4 | Omega-9.lss | 9600,7,E,1 | Untested |
| Seiko | RT-100 ST206/ ST306 Lynx Display Board | RT-100.lss ST206.lss | 9600,8,N,1 9600,7,E,2 9600,8,N,1 | Untested |
| Untested | ||||
| Untested | ||||
| Spectrum | Spectrum.lss | 9600,8,N,1 | Untested | |
| Westerstrand | Sportstimer | Westerst.lss | 1200,8,N,2 | Untested |
Step 3: Configure LynxPad with your scoreboard settings
- From the Script: drop-down list, select the script that corresponds with your scoreboard.
- (Optional) Type a name for the scoreboard in the Name: field, for example, "Finish Line Results."
- (Optional) If necessary, change the Code Set: to Unicode by selecting the radio button.
- Make the following selections:
- Either Serial Port:, Baud, Data Bits, Parity, and Stop Bits if you are connecting LynxPad directly to the scoreboard. Select values you found in the Scoreboard Settings (see "Step 2: Find your scoreboard in the Scoreboard Settings table") table, or
- Select Network Connect: and type the appropriate Port and IP Address values in the text boxes.
Step 4: Configure scoreboard data display
These instructions explain how to configure LynxPad to display:
- event results
- start lists, or
- start lists and results on a scoreboard.
- With the Scoreboard | Options dialog open, click the Manual radio button. This means that results are sent only to the scoreboard when you select Scoreboard | Display current event or Scoreboard | Display Team Scores from the Menu bar.
- With the Paging box checked, type a value in the Size text field that corresponds with the number of lines on your scoreboard. For example, if you have a single line scoreboard, you would type "1."
- To specify the maximum number of results you want the scoreboard to page through, type a value in the Max text field. If this field is left blank, the scoreboard will page through all of the results.
- In the Time text field, type the number of seconds you want each page of data to remain visible on the scoreboard before it scrolls to the next page of data.
- By default, LynxPad sends only the competitor's last name to the scoreboard. Click to check the Include first name box to send the competitor's first and last name to the scoreboard.
- If you want to send the competitor's affiliation abbreviation to the scoreboard, click to check the Affiliation abbreviation box. Affiliation abbreviations (see "4. Set up an athlete affiliation") are based on what you enter in LynxPad.