Existing layouts
Opening an existing layout
- Start at the ResulTV configuration screen (see ResulTV configuration screen).
- Click File and select Open.
- Double-click an RTV file listed in the dialog box. The layout appears on your screen.
note: Several layouts have been provided for your convenience. We recommend that you open an existing layout and then click File | Save As, rename the layout, and modify it for your specific needs.
Creating a new layout or modifying an existing layout
You can create a new, custom layout or you can modify an existing layout.
To create a new, custom layout
- Start at the ResulTV configuration screen.
- Click File | New. A blank layout screen appears.
- Add text and graphics object boxes to the layout by clicking Layout | New text object and Layout | New bitmap object.
- Save the new layout by clicking File | Save and giving the file a name.
To modify an existing layout
- Click File | Open from the menu bar.
- Double-click to open an RTV layout file.
- Click File | Save as, give the file a new name, and then click the Save button. Now you can modify the new layout you just created. The original layout is saved under its original name for later use.
Different RTV files
ResulTV comes with several RTV, or layout files, described here.
remember: If you do not want to use the existing layouts, you can customize existing or create new RTV files (see "Creating a new layout or modifying an existing layout").
Figure: Existing layouts
- 2x1_Video Display.rtv: basic Video Display layout (336x168 pixels) (see Working with Video Display objects)
- 84x168_Results1.rtv: 1 line layout for the Lynx Portable 84x168 pixel LED Video display
- 84x168_Results3.rtv: 3 line layout for the Lynx Portable 84x168 pixel LED Video display
- 84x168_Time.rtv: running time layout for the Lynx Portable 84x168 pixel LED Video display
- 336x168_Results1.rtv: 3 lines and running time layout for the Lynx 1/2/3-Sided LED Video Infield displays
- 1024x768.rtv: configured to work with any 1024x768 pixel display. Fields include: competition name, event name, place, name, affiliation, mark/time, competition sponsor, running time up to 6 lanes.
- 1024x768flag.rtv: configured to work with any 1024x768 pixel display, and is set up for you to display dynamic place (such as medals), affiliation (such as country flags), and event-round-heat (such as FinishLynx) images.
- 1024x768-flags.rtv: configured to work with any 1024x768 pixel display. Fields include: competition name, event name, heat/flight number, place, name, affiliation, flags, mark/time, running time, and up to 8 lanes.
- 1024x768-no-flags.rtv: configured to work with any 1024x768 pixel display. Fields include: competition name, event name, heat/flight number, place, name, affiliation, mark/time, running time, and up to 8 lanes.
- 1024x768swim.rtv: configured to work with any 1024x768 pixel display and Hy-Tek Meet Manager for Swimming as its data source. Fields include: competition name, event name, place, lane, name, affiliation and mark up to 8 lanes.
- 640x480.rtv: fields include those listed for 1024x768.rtv, but configured to work with this smaller size monitor.
- 800x600.rtv: fields include those listed for 1024x768.rtv, but configured to work with this smaller size monitor.
- Time.rtv: fields include competition name, running time, and sponsor. Configured to work with a 640x480 size monitor.
- 1280x720-flags.rtv: configured to work with any 1280x720 pixel display. Fields include: competition name, event name, heat/flight number, place, name, affiliation, flags, mark/time, running time, and up to 8 lanes.
- 1280x720-no-flags.rtv: configured to work with any 1280x720 pixel display. Fields include: competition name, event name, heat/flight number, place, name, affiliation, mark/time, running time up to 8 lanes.
- 1366x768-no-flags.rtv: configured to work with any 1366x768 pixel display. Fields include: competition name, event name, heat/flight number, place, name, affiliation, mark/time, running time, and up to 8 lanes.
- 1366x768-flags.rtv: configured to work with any 1366x768 pixel display. Fields include: competition name, event name, heat/flight number, place, name, affiliation, flags, mark/time, running time, and up to 8 lanes.
- 1920x1080-no-flags.rtv: configured to work with any 1920x1080 pixel display. Fields include: competition name, event name, heat/flight number, place, name, affiliation, mark/time, running time, and up to 8 lanes.
- 1920x1080-flags.rtv: configured to work with any 1920x1080 pixel display. Fields include: competition name, event name, heat/flight number, place, name, affiliation, flags, mark/time, running time, and up to 8 lanes. Shown below.
Figure: Existing layouts
Dynamic image layout
There is a layout available for use with ResulTV that allows you to dynamically display medals, country flags, and FinishLynx images on your ResulTV layout (see example below). Remember that you can still create a custom layout (see "Creating a new layout or modifying an existing layout") when displaying dynamic images. The layout is currently only available in a 1024 x 768 pixel size.
Figure: Existing layouts