FinishLynx "Other Settings"

Every setting behind Ctrl+Shift in FinishLynx — the window you know, with what each setting does and its default. Known to timers as the hidden settings.

Event\Results\CloseToAnother

Refers to conditions prompting the warning, "Another Time is Close" during image evaluation.

-1=Disable

0=Dead Heat Only

1+=Milliseconds

How to change it

  1. In FinishLynx, hold Ctrl+Shift and click File | Options. The Other Settings window opens.
  2. Expand Event, then Results, and select CloseToAnother.
  3. Note the current Value before you change it, then click OK.
  4. The default is 5; set it back to that to undo the change.
  5. Close and reopen FinishLynx so the change takes effect.