FinishLynx "Other Settings"

Every setting behind Ctrl+Shift in FinishLynx — the window you know, with what each setting does and its default. Known to timers as the hidden settings.

Hardware\AIC\PulseSizePIris

Sets the duration of a pulse to adjust the iris by Automatic Iris Control.

Range: 0-7

0=10ms

1=20ms

2=40

*Each value doubles the time of the previous value.

How to change it

  1. In FinishLynx, hold Ctrl+Shift and click File | Options. The Other Settings window opens.
  2. Expand Hardware, then AIC, and select PulseSizePIris.
  3. Note the current Value before you change it, then click OK.
  4. The default is 0; set it back to that to undo the change.
  5. Close and reopen FinishLynx so the change takes effect.

All FinishLynx “Other Settings”