FinishLynx "Other Settings"
Every setting behind Ctrl+Shift in FinishLynx — the window you know, with what each setting does and its default. Known to timers as the hidden settings.
Hardware\SerialWireless\StatusTimeout
Time (ms) waits to receive status packet from RadioLynx before a warning is displayed that the gun sensor failed when arming an event in FinishLynx.
- Type: Int
- Default: 70
*RadioLynx status is sent every 60ms when "Transmitter sends periodic status" is checked.
How to change it
- In FinishLynx, hold Ctrl+Shift and click File | Options. The Other Settings window opens.
- Expand Hardware, then SerialWireless, and select StatusTimeout.
- Note the current Value before you change it, then click OK.
- The default is 70; set it back to that to undo the change.
- Close and reopen FinishLynx so the change takes effect.