FinishLynx "Other Settings"
Every setting behind Ctrl+Shift in FinishLynx — the window you know, with what each setting does and its default. Known to timers as the hidden settings.
LapTime\BibLynx\Debug
Defines when FinishLynx should generate extra debug event(s).
Sum values for multiple events.
0=Disable 1=First Seen 2=Avg Seen 4=Last Seen 8=First Peak
16=Avg Peak 32=Last Peak
64=Log Bad Readings
128=Log Messages
- Type: Int
- Default: 0
How to change it
- In FinishLynx, hold Ctrl+Shift and click File | Options. The Other Settings window opens.
- Expand LapTime, then BibLynx, and select Debug.
- Note the current Value before you change it, then click OK.
- The default is 0; set it back to that to undo the change.
- Close and reopen FinishLynx so the change takes effect.