FinishLynx "Other Settings"

Every setting behind Ctrl+Shift in FinishLynx — the window you know, with what each setting does and its default. Known to timers as the hidden settings.

LapTime\FillPlaceStyle

Controls how the Place field behaves after the first official time is read when FillPlaceField is ON.

0=Never displayed

1=Cleared for unread results

2=Always displayed

How to change it

  1. In FinishLynx, hold Ctrl+Shift and click File | Options. The Other Settings window opens.
  2. Expand LapTime, and select FillPlaceStyle.
  3. Note the current Value before you change it, then click OK.
  4. The default is 0; set it back to that to undo the change.
  5. Close and reopen FinishLynx so the change takes effect.

All FinishLynx “Other Settings”