FinishLynx 11.00

What's New

Time Trial (TT) Plug-in Improvements

The Time Trial (TT) Plug-in is now much more flexible and gives new options to help manage group (wave) starts.

Start Key Selection

Instead of being bound to using the ID as the key field for the Time Trial (TT) Plug-in, it is now possible to have FinishLynx lookup that start using any of these fields:

tip: Examples: 1) Leverage this feature by assigning a wave number in the User 3 field of each participant in LynxPad or your favorite results management application. 2) Your event will start 1 wave for each school in each division, simply use the Affiliation as the Start Key and all members of the school will be assigned dedicated start time.

  1. Create a new event.
  2. Click the Key field in the Time Trial row of the Information Zone.
  3. Select the preferred field from the pop-up dialog.

Figure: FinishLynx 11.00

note: The start Key field supports up to 30 characters.

Filter Support of Start Key

The Start drop-down menu in the Results Filter dialog now includes the start key. This should make it easier to figure out which start you want to select for a filter.

Additional Options

A number of controls are also available to tailor how each new start is managed. See the ADVANCED - Other Settings section below.

Lynx Wind Module Improvements

The Lynx Wind Module now sends readings back using the same connection when an event receives a reading, when a reading is selected from the list, and when a reading is manually entered. This is intended to allow controlling the wind gauge from FinishLynx and displaying the reading on a Gill E49821 & E49822 Countdown Timer in Wind mode connected to the Standalone Wind Gauge Controller using only 1 serial port.

  1. Configure FinishLynx to use the Lynx wind module.
  2. Select FL-DISPLAY on the Standalone Wind Gauge Controller.
  3. Connect the Lynx wind gauge to the Controller and a serial port (e.g. C-BOX or Camera Back). Note: Y-splitter required.
  4. Connect the Gill Countdown Timer in Wind Mode to the Controller.

note: The data sent back to the wind gauge is in a fixed format required by the Standalone Wind Gauge Controller that will convert the format for supported display (currently Gill and Ostar). Compatible with Standalone Wind Gauge Controller 1.31 and newer.

Scoreboard Module Improvements

When the running time is in the Paused or Finished state the scoreboard module will now re-send the data if anything in the Event changes. This is intended primarily to allow a wind reading that comes in while in one of these states to be sent out immediately, but it will allow any Event data to be sent immediately.

Lynx Data Port (LDP) Plug-in

The Lynx Data Port (LDP) Plug-in is the latest addition to the FinishLynx plug-in family and gives a new solution for remote applications to access FinishLynx event data over the network. LDP is meant for programmers that have specific objectives such as streaming image frames or analyzing them using AI technology. If you're interested in knowing more about the Lynx Data Port (LDP) Plug-in, contact Tech Support.

General Optimization

FinishLynx is optimized to deal with large lists of participants and manage a high rate of events from a LapTime device. This includes:

note: Running FinishLynx as Administrator (right-click shortcut + Run As Administrator) for best performance.

ADVANCED - Other Settings

Additional Other settings are included:

tip: Add values together to combine options. For example, if you have set up the User3 field and have numbered groups from 1 to n, then set this value to 210 to have all start key automatically increment from 1 with each new start.

tip: The purpose of CheckWait is to wait a little while to see if more readings come in so that fewer updates are done. Regardless of the CheckWait value, if CheckMax is reached readings will be transferred immediately.0

note: These advanced settings are for experienced users only. For more information on how to access these settings, please contact our support team.