Nevco

FinishLynx connects to a Nevco scoreboard through the Nevco FinishLynx Interface, a small box that takes RS-232 serial from the FinishLynx computer and sends coax to the scoreboard's wall jack. The script depends on the MPC Control model code, and the wrong script is the most common cause of a blank or wrong display.

How to fix it

Find your script

  1. Read the model code on your MPC Control and pick the matching script:
    • Nevco_860.lss: models 7404, 7504, 7416, 7516, 7520, 7424, 7524, 7430, 7530
    • Nevco_123.lss: models 7405, 7505, 7425, 7525
    • Nevco-x6xx.lss: models 7604, 7614, 7615, 7616, 7620, 7624, 7625, 7630, 7631, 7632, 7680-EC, 7685-EC, 7688-EC
  2. If the script isn't in the Script list in FinishLynx, download it from Nevco scoreboard scripts, save it in C:\Lynx, and close and reopen FinishLynx.
  3. If your model number isn't listed, Lynx can tell you which script to use.

Connect the hardware

  1. Wired: connect the RS-232 serial cable from the FinishLynx computer to the serial port on the Nevco Interface, and the coax cable from the Interface to the scoreboard's wall jack. Plug in the 9VDC power supply.
  2. Wireless: the same RS-232 connection at the FinishLynx end, to the Wireless Interface. The MPCX receiver at the scoreboard connects by coax to the wall jack. The wireless units are paired at the factory.
  3. With FinishLynx, the Interface must be on the wall jack, not the MPC Control. For normal scoreboard operation without FinishLynx, reconnect the MPC Control to the wall jack.

Set up FinishLynx

  1. Go to Scoreboard | Options and click New.
  2. Set Script to the script you found above.
  3. Set Serial Port to the COM port connected to the Nevco Interface, with Baud 57600, Data Bits 8, Parity None, Stop Bits 1.0.
  4. Set Running Time and Results to your preference.
  5. Click OK and restart FinishLynx.

If the board shows nothing or the wrong data

  1. Confirm the script matches your scoreboard model.
  2. Check the Nevco Interface has power (the LED should be on).
  3. Confirm the COM port in FinishLynx is the port the serial cable is on.
  4. Check no other FinishLynx option, such as the capture button, uses the same COM port (File | Options | General tab).
  5. Check the coax connections between the Interface and the scoreboard wall jack.

For the Interface box or the scoreboard itself, Nevco's support line is 800-851-4040 and the latest instructions are on Nevco's website.

Good to know

The FinishLynx Wireless Interface works only with the MPCX receiver, not the MPCW-5, MPCW-6, MPCW-7, MPCX2 or MPCHA receivers.

Talk to Lynx Support

Tell the team what you’re seeing and what you’ve already tried. They’ll follow up by email or phone.

Contact Support