Hy-Tek Meet Manager as a data source

Hy-Tek Meet Manager for Track and Field

Configuring ResulTV for use with Meet Manager for Track and Field

  1. Click File | Options from the menu bar on the ResulTV configuration screen. The Options dialog appears.
  2. Go to the Sources tab. Click the New button.
  3. Tab to the Script: drop-down list and select Hytek.rss.
  4. Tab to the Name: text field and type a new name for your data source, for example, Hy-Tek Database.
  5. Tab to the Serial Port: drop-down list and select the correct COM port from the drop-down list.
  6. Click OK and restart ResulTV. ResulTV is now configured to receive data from the Hy-Tek Meet Manager computer.

Configuring Meet Manager Track and Field for Windows for use with ResulTV

note: The instructions provided here are for the convenience of our customers. Because Meet Manager for Track and Field is a software program designed by Hy-Tek, Ltd., the instructions below may not be valid for versions later than 1.2. Please refer to the Hy-Tek website (www.hy-tekltd.com) for more information.

Pre-requisites

If you are sending data from Meet Manager to ResulTV over a serial connection (see "Using ResulTV over a serial connection"), make sure the computers are connected with a null modem cable.

Instructions

  1. Run Hy-Tek Meet Manager.
  2. Click Set-up from the menu bar and select Alpha Scoreboard Interface from the drop-down menu. The Scoreboard Vendor dialog appears.
  3. Select the Daktronics Fixed Digit radio button and then click OK.
  4. Click Run from the menu bar. The Run the Meet screen appears.
  5. Click Interfaces from the menu bar and select Scoreboard - Daktronics Fixed Digit | Open/Close Serial Port. The Select Serial Port for Daktronics Fixed Digit dialog appears.
  6. Click in the Serial Port for Scoreboard (0-16) field and then type the number of the COM port on the Meet Manager computer that is connected to the null modem cable going to the ResulTV computer.
  7. Go To Interfaces | Scoreboard – Daktronics Fixed Digit | Customize. Enter the number of results per page to be shown in ResulTV and specify Lane or Finish order. Confirm Baud Rate is 9600, number of seconds each page of results is shown, and Metric vs English for field event results. You can also customize how names are shown (upper case, last name only, etc.). Click OK.

Hy-Tek Meet Manager for Swimming

Configuring ResulTV for use with Hy-Tek Meet Manager for Swimming

  1. Click File | Options from the Menu bar on the ResulTV configuration screen. The Options dialog appears.
  2. Go to the Sources tab. Click the New button.
  3. Tab to the Script: drop-down list and select HytekSwim.rss.
  4. Tab to the Name: text field and type a new name for your data source, for example, Hy-Tek Database.
    • Tab to the Serial Port: drop-down list and select the correct COM port from the drop-down list.
  5. Click OK. ResulTV is now configured to receive data from the Hy-Tek Meet Manager computer.

Configuring Meet Manager Swimming for use with ResulTV

note: The instructions provided here are for the convenience of our customers. Because Meet Manager for Swimming is a software program designed by Hy-Tek, Ltd., the instructions below may not be valid for versions later than 1.4. Please refer to the Hy-Tek website (www.hy-tekltd.com) for more information.

Pre-requisites

If you are sending data from Meet Manager to ResulTV over a serial connection (see "Using ResulTV over a serial connection"), make sure the computers are connected with a null modem cable.

Instructions

  1. Run Hy-Tek Meet Manager.
  2. Click Set-up from the menu bar and select Alpha Scoreboard INTERFACE from the drop-down menu. The Scoreboard Vendor dialog appears.
  3. Select the Generic Serial radio button and then click OK.
  4. Click Run from the menu bar. The Run the Meet screen appears.
  5. Click Scoreboard (Genser) from the menu bar and then select Open/Close Serial Port for GENSER. The Select Serial Port for GENSER dialog appears.
  6. Type the number of the COM port on the Meet Manager computer that is connected to the null modem cable going to the ResulTV computer.
  7. Click OK. Meet Manager is now ready to send data to ResulTV.
  8. To send a start list, simultaneously press the Ctrl and F10 keys on the Meet Manager computer. To send Results, simultaneously press the Ctrl and F11 keys on the Meet Manager computer.