Other code
A boot error other than 129, 201 or 202 usually means FinishLynx found a connection or hardware problem partway through the boot. Errors 129, 201 and 202 each have their own page under Boot error on screen; for everything else, start by simplifying the connection.
How to fix it
Simplify the connection
- Swap the network cables one at a time to rule a cable out
- Boot the camera without the network switch, cabled straight to the computer. Use a PoE injector to power it
- Work through the Camera Boot Troubleshooting Guide: computer settings, FinishLynx settings and cables
- Read the BOOT light: solid red for more than a minute is a boot failure, flashing amber means the camera booted and is waiting for FinishLynx, solid green means it loaded. Each has a page under FinishLynx not finding camera
- On an EtherLynx 2000 whose boot stops partway with a string of error codes, see Boot stops partway (2000 camera)
If the problem comes and goes, save the camera's log files
- Restart the camera once and note whether the problem clears after a fresh start
- With the camera loaded, hold Ctrl+Shift and open Camera Settings, then the Timer tab
- Click Download Log files
- Still can't boot the camera? Use the button below. The log files show Lynx what failed
Talk to Lynx Support
Tell the team what you’re seeing and what you’ve already tried. They’ll follow up by email or phone.
Related resources
- Camera Boot Troubleshooting Guide — Guide · PDF