Error booting camera
The error number tells you where to look. Error 202 is a Windows permissions problem that running FinishLynx as administrator fixes, not camera damage; a boot that keeps cycling between "starting" and "initializing" is a network or camera problem.
How to fix it
If the error number is 202
Error 202 means FinishLynx does not have the Windows permissions it needs to communicate with the camera. It often shows as the camera loading to 32% and then stopping with Error 202.
- Close FinishLynx
- Right-click the FinishLynx shortcut and select Run as administrator
- To make FinishLynx run as administrator every time:
- Create a desktop shortcut for FinishLynx, right-click it and go to Properties
- On the Shortcut tab, click Advanced, check Run as administrator and click OK
- If it still fails, check that no other device on the network is using the camera's IP address
If it still stops at 32% as administrator
If other cameras load on the same computer but this one keeps stopping at 32%, the camera itself is the likely fault and needs a repair: submit an RMA and send it in to Lynx.
If the boot keeps cycling between starting and initializing
- Work through Network switch activity, including the discovery-utility test
- On a slow or managed network where the camera boots but FinishLynx gives up first, see the boot wait time card on the FinishLynx Other Settings page
- If it still cycles when connected straight to a computer on its supplied injector, fails the same way on a second computer, and the discovery utility can't find it, the camera needs a repair: submit an RMA and send it in to Lynx
If the error number is anything other than 202
Lynx needs to see it: use the button below and include the error number and what the camera was doing.
Send it in for repair
Start an RMA. The portal walks you through what to include and where to ship it.