Network switch activity
The switch shows a link for the camera, so the camera is powered and on the network: the cause is on the computer or in FinishLynx. Start with the FinishLynx settings and work down the list in order; if the camera loads on one computer but not another, compare the FinishLynx versions first.
How to fix it
Check the FinishLynx settings
- In FinishLynx, open File | Options | General and set Hardware Type to Detect
- Under Camera Network, choose the address of the Ethernet adapter the camera is on (192.168.0.5 on the standard setup), click OK and restart FinishLynx
- The Camera Network list can't be typed into: it lists the IP addresses of the computer's network adapters. If the address isn't there, set it in Windows (next section) and it appears here
- If two addresses in the list share the same first three numbers (the same subnet), another adapter is in conflict, often Wi-Fi after a Windows update. Close FinishLynx, turn Wi-Fi off (below), then reopen FinishLynx: the camera should now load
Give the Ethernet adapter a static IP address
- Give the computer's Ethernet adapter a static IP address in Windows: 192.168.0.5 is the Lynx recommendation. With 192.168.0.5 the camera boots as 192.168.0.6
- FinishLynx gives each camera the next IP address up from the computer's Ethernet adapter, so make sure no other device on the network uses those addresses
Turn Wi-Fi off while the cameras boot
- In Settings | Network & internet, turn Wi-Fi Off
- Wi-Fi can be used after the cameras have loaded if it's on a different subnet from the camera network. Lynx recommends keeping Wi-Fi off on timing laptops if possible, and doing internet work (live results, meet management) on a separate computer
Allow FinishLynx through the firewall
- Open Windows Security | Firewall & network protection | Allow an app through firewall and click Change settings
- Check the box to the left of Lynx plus the Private and Public columns
- If Lynx isn't listed, click Allow another app..., browse to
C:\Lynx\Lynx.exeand check the same boxes - Check this again after a Windows update: an update can clear the permission
- The full computer checklist (run as administrator, adapter power saving, antivirus) is in Flashing amber BOOT light. It applies to IdentiLynx and VeriLynx cameras too
Check the white list
- In FinishLynx, go to Help | Find Cameras...
- If you are not using a white list on purpose, make sure Use White List is unchecked
- If you are using one, make sure the IdentiLynx or VeriLynx is on it: select the camera in the list and click Add
Check your FinishLynx version
- Check the label on the back of the camera for the minimum FinishLynx version it needs. The IdentiLynx SR-2 and HRS need FinishLynx 12.10 or later
- In FinishLynx, go to Help | About to see your version. If the camera loads on one computer but not another, compare the version on each
- If your version is older than the label says, update FinishLynx
- Note your software serial number from Help | About, then close FinishLynx
- Download and install the latest version from the Software page, entering your serial number when prompted
- Reopen FinishLynx
Check the boot order
- Open FinishLynx and power on the EtherLynx cameras first
- Once they appear in the Hardware Control window, connect the Ethernet cable to the IdentiLynx (the IdentiLynx SR-2 & HRS Setup QSG has the full setup)
Test the camera with the discovery utility
- Download the camera finder for your model from the Software page (Drivers & Utilities): IP-Toolbox for the IdentiLynx SR, SR-2 and HRS, or IQfinder for older models such as the B91, B95 and IDL031. The model is on the camera's label
- Install it and run it with the IdentiLynx connected
- If the camera is listed, it is on the network and its settings need checking: use the button below
- If the camera is not listed, see No network switch activity
Talk to Lynx Support
Tell the team what you’re seeing and what you’ve already tried. They’ll follow up by email or phone.
Related resources