Ready to Start light not working with FinishLynx
With FinishLynx, the VeriLight is driven like a scoreboard: a scoreboard entry with the VeriLight_Ready.lss script sends the event status to the light. When the light never changes, the entry is usually missing a setting, the hidden TCPEchoBytes value was not set, or FinishLynx was not restarted after the change.
How to fix it
Check the scoreboard entry
- Go to Scoreboard | Options… and select the VeriLight entry, or click New if there is none. Give it a clear name, such as "VeriLight".
- Set Script to VeriLight_Ready.lss.
- Set Serial Port to Network(connect), Port 10000, and IP address 192.168.0.99 (or the address you gave the light).
- Set Running Time to Normal and Results to Off.
- Click Ok and restart FinishLynx.
Set the hidden setting (the step most often missed)
- Hold Ctrl+Shift and click File | Options… to open the Other Settings.
- Set Scoreboards\1\TCPEchoBytes to 0, using your VeriLight entry's number in place of 1.
- The number is the entry's position in the Scoreboard | Options list: the first scoreboard is 1, the second 2. Expand +Scoreboards, then +[#], and the Name setting under it shows the name you gave the entry.
- If there is no +[#] for it yet, save the entry, restart FinishLynx and look again.
- Click Ok and restart FinishLynx.
The VeriLight Ready light card on the FinishLynx Other Settings page shows the setting and how to change it.
What the light should do
- Event armed (ready to start): flashes green
- Event running: off
- Event finished: solid red, on the photoeye break. Since FinishLynx 13.00 it also turns red when the first result is entered if no photoeye is used.
If the light still never changes
- Ping the light's IP address from a Command Prompt, and type the address into a browser. If neither works, fix the network first: see Initial connection and IP setup.
- Check the FinishLynx computer has a static IP address on the light's subnet (for example 192.168.0.5 for a light at 192.168.0.99).
- The VeriLight has no on/off switch. It is on whenever it is connected to PoE power.
- Update FinishLynx if it is older than the version the VeriLight Quick Start Guide lists. FinishLynx also needs the Network ComPort (NCP), built in since 13.00.