Initial connection and IP setup
VeriLight is an indicator light that runs on Power-over-Ethernet and is controlled over the network by FinishLynx, FieldLynx or VeriLynx. Out of the box it answers on IP address 192.168.0.99, port 10000, and its web page password is Lynx.
Most first-time problems come from the cable going into the wrong port on the power injector, or the computer not being on the same network as the light.
How to fix it
Connect the hardware
- Place the VeriLight on the ground where officials, athletes or spectators can see it.
- Plug the Power-over-Ethernet power supply into a power outlet or a UPS battery backup.
- Run an Ethernet cable from the PC to the network switch, or to the In port of the VeriLight power supply.
- Open the panel on the back of the VeriLight with a Philips screwdriver. Run a long Ethernet cable from the RJ45 port inside to the switch, or to the Out port of the power supply.
- If you are using a PoE+ switch, the power supply is not required. Lynx recommends a PoE+ Gigabit switch.
- There is no on/off switch: the light turns on as soon as it gets PoE power through the cable.
Check the computer can reach it
- On the computer, open a web browser and go to 192.168.0.99.
- Enter the password Lynx. If the page opens, the computer is talking to the light.
- If nothing loads, try 192.168.10.1 instead. That is the factory address, and a light that has never been set up may still be on it.
- You can also open Command Prompt and run
ping 192.168.0.99(or the light's address). No reply means a cable, power or IP problem, not a FinishLynx setting. - Check the computer runs software that can drive the light: FinishLynx 13.00 or later (the Network ComPort is built in; 12.21 works with the NCP plug-in installed), FieldLynx with the Scoreboard plug-in, or FieldLynx Lite.
- For the network side of a scoreboard on the FinishLynx computer, see Connecting a new scoreboard.
Change the IP address
- Open a web browser and go to the light's current address (192.168.0.99, or 192.168.10.1 from the factory).
- Enter the password Lynx.
- Click Network Setup, under Communication Setup in the left banner.
- Set the IP address you want and click Set.
- Enter the same address in the software: Scoreboard | Options in FinishLynx, or Options | Preferences | Scoreboard tab in FieldLynx.
Setup steps for each program are in the VeriLight Quick Start Guide, and the VeriLight Datasheet lists the minimum software versions. Once the light is reachable, see Ready to Start light not working with FinishLynx or Foul light not working with FieldLynx or VeriLynx.
Good to know
Ethernet cables are not included with the light unless ordered.
Related resources
- VeriLight Quick Start Guide — Guide · PDF