Foul light not working with FieldLynx or VeriLynx
As a foul indicator the VeriLight shows red for a foul and green for a valid mark. With FieldLynx or FieldLynx Lite it is a scoreboard with the VeriLight.lss script. With VeriLynx it is run from a VeriLight menu that only appears once the FinishLynx profile is VeriLynx and the program has been restarted.
How to fix it
FieldLynx or FieldLynx Lite
- Go to Options | Preferences… and click the Scoreboard tab.
- Click New.
- Set Script to VeriLight.lss.
- Set Serial Port to Network(connect), Port 10000, IP address 192.168.0.99 (or the address you gave the light).
- Click the Advanced button and uncheck both boxes: Send scoreboard data byte-by-byte (Legacy) and Send scoreboard data line-by-line (Legacy).
- Click Ok and restart FieldLynx.
- Press Alt-M for a valid mark to toggle green on or off. The Message dialog must be empty for this to work.
- Press X to enter a foul. The light turns red with the next scoreboard update. Press Alt-I to initialize the light and turn it off.
VeriLynx (FinishLynx with the VeriLynx profile)
- In FinishLynx, go to File | Options… and click the General tab.
- Set Profile to VeriLynx and click Ok.
- Exit and restart FinishLynx. The VeriLight menu appears after the restart.
- Click VeriLight | Foul (Toggle On/Off), or press Alt-F, to toggle red on or off.
- Click VeriLight | Valid (Toggle On/Off), or press Alt-V, to toggle green on or off.
- Go to VeriLight | Options… to change the light's settings.
For the light's network side, see Initial connection and IP setup. For FieldLynx scoreboard settings in general, see Scoreboard plug-in and settings. The VeriLynx Basics video covers VeriLynx configuration and operation.
To show the foul and valid images on a ResulTV screen as well, see Wind colors, foul/valid images and custom colors.
Good to know
FieldLynx needs the Scoreboard plug-in (version 1.54 or later per the datasheet) to drive the light. FieldLynx Lite does not need a separate plug-in.