Output options

Portable-VDM accepts data from FinishLynx, FieldLynx, LynxPad and ScorePlus. FinishLynx, FieldLynx and LynxPad send through the ResulTV-Video scripts over Network (connect) on port 1024, to the MiniPC's IP address for your connection method.

ScorePlus is the exception: it runs on the MiniPC itself and needs no script. If the connection is not up yet, start with Initial connection.

How to fix it

Set up FinishLynx to send data

  1. Open FinishLynx and go to Scoreboard | Options….
  2. Click New to create a new scoreboard output.
  3. Set Script to ResulTV_Video_1line.lss.
  4. Set Serial Port to Network (connect), Port to 1024, and the IP address to the MiniPC's address for your connection method.
  5. Set Running Time to Normal and check Force Stop.
  6. Set Results to Auto and Size to 1, check Always send place, then click OK.
  7. Close and restart FinishLynx.

Set up FieldLynx (or FieldLynx Lite) to send data

  1. Open FieldLynx or FieldLynx Lite and go to Options | Preferences….
  2. Select the Scoreboard tab. FieldLynx Lite already includes the Scoreboard plug-in; full FieldLynx needs the separate FieldLynx Scoreboard plug-in.
  3. Click New to create a new scoreboard source.
  4. Set Results Scripts (Metric and English) to ResulTV_Video_results.lss and Standings Scripts to ResulTV_Video_standings.lss.
  5. Set Serial Port to Network (connect), Port to 1024, and the IP address to the MiniPC's address for your connection method.
  6. Close and restart FieldLynx.

Run ScorePlus from a phone

  1. Connect your phone to the same network as the Portable-VDM (the Portable-VDM1 Wi-Fi hotspot, or the Lynx network).
  2. Scan the QR code shown on the display. The ScorePlus interface opens.
  3. Select your Sport and open the Operate tab.
  4. Use the on-screen controls to run the clock, quarter and score. The ScorePlus video tutorial shows it in use.

Adjust the display window with @ commands

ResulTV-VDM accepts command messages that begin with @ to control the display remotely. In FinishLynx, go to Scoreboard | Edit Messages…, type the command in the message field and click Send. For example, to set the display to 208 x 104 pixels, enter @resize 208x104 and click Send.

  1. @resize W,H resizes the display window (width and height in pixels, minimum 50).
  2. @position X,Y moves the display window (X and Y screen coordinates in pixels).
  3. @top yes/no turns always-on-top mode on or off.
  4. @scroll yes/no turns horizontal ticker scrolling on or off.
  5. @image <path> sets the base folder used to resolve ImageDraw file names.
  6. @screens N sets how many physical screens the display spans (1 to 8).
  7. @profiles <name> switches to a named display profile.

Good to know

Only the first @ command in a message line is processed, arguments are not case-sensitive, and unknown commands are ignored.