Portable-VDM is ResulTV-VDM on a battery-powered Windows MiniPC in a weatherproof box. It comes preconfigured to listen for data on Network (listen), port 1024, and most first-connection problems come down to the HDMI link, the network method, or an IP address that does not match. Work through these in order.
The Portable-VDM with ScorePlus QSG covers all of this, and the Portable-VDM datasheet lists what is in the box.
How to fix it
Connect the display (HDMI)
- Connect the MiniPC to the LED display's video sending unit with an HDMI cable. The cable is not included with the Portable-VDM; one came with your Lynx LED display.
- Turn on the Portable-VDM with the power switch on the battery pack and allow about 2 minutes for startup.
Choose one network method and use its IP address
Check the label on the device for the configured IP address and port before you begin. Pick the method that fits how you work:
- Wired Ethernet (recommended for FinishLynx data): a cable to the MiniPC's Ethernet port, IP 192.168.0.70, port 1024.
- AirLynx (recommended for FieldLynx data): the access point with SSID Lynx, IP 192.168.0.71, port 1024.
- Your computer may need a static IPv4 address on the same subnet, such as 192.168.0.50 with subnet mask 255.255.255.0. See Device can't join or drops out.
- MiniPC Wi-Fi hotspot (recommended for ScorePlus and FieldLynx data): Wi-Fi SSID Portable-VDM1, IP 192.168.50.1, port 1024.
Point your software at the MiniPC
- In FinishLynx, FieldLynx or ScorePlus, set the scoreboard output to Network (connect), port 1024, and the MiniPC's IP address for the method you chose. The full settings are in Output options.
- If you switched network methods after setup, reboot the MiniPC: turn the battery pack off and back on. Changing methods without a reboot is a common reason the connection won't come up.
- To shut down properly, press and hold the power button on the MiniPC until it shuts down, then switch off the battery pack.
Remote access and battery
- For advanced configuration, reach the MiniPC from a Windows computer on the same network with Remote Desktop Connection: enter the MiniPC's IP address, user name Lynx, no password.
- To charge, connect the wall charger to a standard 110/240 V AC outlet. The LED light bar shows when the battery is full; a full charge runs the unit for more than 10 hours.
If your HDMI cable has failed
- The display takes video over HDMI only, like a monitor, so there is no way to feed it over Ethernet.
- The network carries results to the MiniPC; the MiniPC's HDMI output carries the picture to the display.
- Replace the cable with any standard HDMI cable. See Lynx Portable Display.