Connection to FinishLynx
XCScore calculates cross country team scores from the results FinishLynx produces, then passes them to ResulTV for display. FinishLynx sends to XCScore over the network with the XCScore.lss scoreboard script on port 1025: a different port from the 1024 that XCScore uses to feed ResulTV.
XCScore must be installed and running on its computer before you connect.
How to fix it
Set up FinishLynx to send to XCScore
- Make sure XCScore is running, and note its computer's IP address (use 127.0.0.1 if FinishLynx and XCScore are on the same computer).
- In FinishLynx, click Scoreboard | Options…. The Options dialog appears.
- Click New to create a new scoreboard.
- From Script, select XCScore.lss.
- From Serial Port, select Network (connect).
- In the Port field, type 1025.
- In the IP Address field, type the IP address of the XCScore computer.
- Set Running Time to Off.
- Set Results to Auto, uncheck Paging, and click OK.
- Close and restart FinishLynx.
Test the connection
- In FinishLynx, open an event (File | Open…) and load a race.
- The results appear in XCScore and team scores are calculated. During a live event, XCScore updates as new results are created or entered in FinishLynx.
For getting those calculated scores onto the display, see Connection to ResulTV. The same steps with screenshots are in the XCScore QSG, and the XCScore Software Tutorial walks through the whole setup.
Related resources
- XCScore QSG — Guide · PDF