Error 202
Error 202 ("Bad Set IP Address") means FinishLynx couldn't give the camera its IP address. The usual cause is Windows permissions: FinishLynx has to run as administrator on the computer that loads the cameras. The message "TCP/IP is not installed or not configured properly" has the same fix.
How to fix it
Run FinishLynx as administrator now
- Close FinishLynx
- Right-click the FinishLynx icon and choose Run as administrator
- Reboot the camera so FinishLynx loads it again
Make it the default
- Right-click the FinishLynx shortcut and choose Properties
- On the Compatibility tab, check Run this program as an administrator and click OK
If Error 202 comes back
- Make sure the Ethernet adapter the camera is plugged into has a static IP address (192.168.0.5 on the standard setup)
- In File | Options | General tab, set Camera Network to that address, then restart FinishLynx and reboot the camera
- Make sure no other device on the network uses the camera's address. FinishLynx gives each camera the next address up from the computer's, so the first camera is 192.168.0.6 and the second 192.168.0.7
- On a new or replaced computer, work through the full checklist for a Flashing amber BOOT light
IdentiLynx or VeriLynx camera
- An IdentiLynx or VeriLynx that loads to 32% and then shows Error 202 has its own page: Error booting camera
Good to know
In a two-computer capture-and-evaluate setup, run FinishLynx as administrator on the capture computer that loads the cameras. On the evaluate computer (Hardware Type set to None), leave Run as administrator unchecked.