Camera dropping randomly
A camera that goes red in FinishLynx has lost its connection to the software. First rule out the other computers on the network, then use the BOOT light on the back of the camera to tell whether the camera stayed powered: that decides where to look next.
How to fix it
Check the other computers on the network
- Only one FinishLynx should look for cameras. On every other computer on the network running FinishLynx, set Hardware Type to None (File | Options | General tab) and restart FinishLynx
- Make sure only one copy of FinishLynx is running on the timing computer
- If any computer on the network runs Windows 11, apply the Windows 11 print fix (the legacy print dialog setting) on every Windows 11 computer on the network, even ones that never print: Slow start or printer warning
Still solid green: the camera stayed on
- Make sure no other computer or device on the network is using the camera's address (by default, one above the timing computer's)
- Check the network cables and the whole connection path between the camera and the computer
- In Device Manager | Network adapters, open your Ethernet adapter's Properties, set Energy Efficient Ethernet to Disabled and uncheck "Allow the computer to turn off this device to save power"
- With a USB-to-Ethernet adapter, also turn off power saving under Device Manager | Universal Serial Bus controllers
- Test a USB-to-Ethernet adapter: open Network Connections, wiggle the adapter and watch whether the Ethernet connection flips to "Network cable unplugged". Replace a flaky adapter and place it where it won't get bumped
- Wi-Fi: off while the cameras boot, and only on a different subnet from the camera network after they load. Check that Camera Network (File | Options | General tab) is the wired adapter's address and there is no second address on the same subnet
- Lynx recommends keeping Wi-Fi off on timing laptops if possible, and doing internet work (live results, meet management) on a separate computer
- Check that antivirus software isn't blocking FinishLynx traffic, and try FinishLynx on a second computer to rule out the PC
Back to flashing amber: the camera lost power
- The camera turned off and back on and has to reload into FinishLynx. If it stays at flashing amber, see Flashing amber BOOT light
- Check the camera's power source for a reason it may have cycled off and on
- If every camera drops at the same moment, check whether the PoE switch powering them lost power for a moment
- With several cameras on one PoE switch, check the switch's total PoE budget as well as the per-port rating: each Vision-series camera can draw up to 30 W (802.3at PoE+) and each IdentiLynx up to 18.72 W. See Camera won't power from the switch
- If nothing obvious turns up, watch whether the camera turns off and back on in a repeating cycle. A repeating power cycle points to a hardware fault: submit an RMA and send the camera in
ON light red: the camera switched itself off
- On a Vision-series camera, if its power source didn't cut out, the camera needs a repair: submit an RMA and send it in
- A common cause is the rear overlay, the back panel that holds the power button. When it fails it can act as if the power button is being held down and turn the camera off
Test the link speed (Vision-series, Pro, Fusion and 2000+)
- These cameras connect at 100 Mbps or faster. Connect the camera directly to the computer with a known-good cable
- Open Settings | Network & internet | Ethernet and look at the link speed in the adapter's properties
- On Windows 10: Control Panel | Network and Sharing Center | Change adapter settings, then double-click the Ethernet adapter and read Speed
- If it shows 10 Mbps, that points to a hardware fault in the camera: send it in for repair
Send it in for repair
Start an RMA. The portal walks you through what to include and where to ship it.