FieldLynx connection

ResulTV shows FieldLynx results through a source of its own that listens on its own port, while FieldLynx sends with the ResulTV_Video scripts on Network (connect). FieldLynx Lite works the same way; full FieldLynx needs the Scoreboard plug-in.

How to fix it

Add a FieldLynx source in ResulTV

  1. Go to File | Options | Sources tab and click New to add a second source.
  2. Set Script to Video Display.rss.
  3. Set Serial Port to Network (listen) and Port to 1025, or any port not already in use. FinishLynx normally has 1024.
  4. Click OK, and restart ResulTV if the status says Not Loaded.
  5. After reopening, click File | Open… and open the Video Display.rtv layout.

Point FieldLynx at it

  1. On the FieldLynx device, go to Options | Preferences | Scoreboard tab and click New.
  2. Set Metric and English to ResulTV_Video_results.lss, and Standings Script to ResulTV_Video_standings.lss.
  3. Set Serial to Network (connect).
  4. Set Port to the port you set in ResulTV, and IP Address to the IP address of the ResulTV computer.
  5. Click OK, then close and reopen FieldLynx. Back on the Scoreboard tab the Status should read Running.
  6. With an event open, use the scoreboard button to send the mark or the standings.

Nothing arriving, or gibberish on screen: see Connection to ResulTV (or Connection to ResulTV). The ResulTV side of a Video Display layout is in Working with Video Display objects.

Good to know

The ResulTV_Video_results.lss and ResulTV_Video_standings.lss scripts came with FieldLynx 1.92 (Scoreboard plug-in 1.53) and need ResulTV 6.21 or later, so update both programs if they aren't in your lists.