FieldLynx connection
ResulTV shows FieldLynx results through a source of its own that listens on its own port, while FieldLynx sends with the ResulTV_Video scripts on Network (connect). FieldLynx Lite works the same way; full FieldLynx needs the Scoreboard plug-in.
How to fix it
Add a FieldLynx source in ResulTV
- Go to File | Options | Sources tab and click New to add a second source.
- Set Script to Video Display.rss.
- Set Serial Port to Network (listen) and Port to 1025, or any port not already in use. FinishLynx normally has 1024.
- Click OK, and restart ResulTV if the status says Not Loaded.
- After reopening, click File | Open… and open the Video Display.rtv layout.
Point FieldLynx at it
- On the FieldLynx device, go to Options | Preferences | Scoreboard tab and click New.
- Set Metric and English to ResulTV_Video_results.lss, and Standings Script to ResulTV_Video_standings.lss.
- Set Serial to Network (connect).
- Set Port to the port you set in ResulTV, and IP Address to the IP address of the ResulTV computer.
- Click OK, then close and reopen FieldLynx. Back on the Scoreboard tab the Status should read Running.
- With an event open, use the scoreboard button to send the mark or the standings.
Nothing arriving, or gibberish on screen: see Connection to ResulTV (or Connection to ResulTV). The ResulTV side of a Video Display layout is in Working with Video Display objects.
Good to know
The ResulTV_Video_results.lss and ResulTV_Video_standings.lss scripts came with FieldLynx 1.92 (Scoreboard plug-in 1.53) and need ResulTV 6.21 or later, so update both programs if they aren't in your lists.