The VeriLight has no battery or wall plug of its own. It is powered over the Ethernet cable, from the PoE power injector or a PoE+ switch, so a dead light usually means power is not reaching the cable that goes into the light. A cracked or wet light needs Lynx to look at it.

How to fix it

No power

  1. Check the PoE power supply is plugged into a working outlet or UPS.
  2. Check the Ethernet cable to the light comes from the Out port of the power supply, not the In port. The In port is for the cable from the PC or switch.
  3. Open the panel on the back of the light (Philips screwdriver) and check the Ethernet cable is seated in the RJ45 port.
  4. Try a different Ethernet cable. Cables are not included with the light, so a bad cable is a common cause. See Choosing a cable.
  5. If you power it from a switch, the switch must supply PoE+ (the light runs on 48V DC PoE). Try the power injector instead. For switch power problems see Camera won't power from the switch.

Damage

  • The light is rated IP54 and for -10°C to +50°C.
  • A cracked or wet light needs a repair: submit an RMA and send it in to Lynx. Warranty is as per regional requirements, and Lynx will tell you whether the light is covered.

Good to know

Do not keep running a light with a cracked housing or a wet connector.

Send it in for repair

Start an RMA. The portal walks you through what to include and where to ship it.

Submit an RMA