Connection to NetExchange

FieldLynx connects to NetExchange when both are on the same network and FieldLynx's Database tab points at the NetExchange computer's IP address and port. NetExchange is the bridge between the meet manager (HyTek, LynxPad and others) and FieldLynx: it hands over the event files and passes the marks back.

A Load Schedule that stays on Connecting is most often an old version on one side, a firewall, or the two computers on different subnets.

How to fix it

Update both programs

  1. Install the current FieldLynx 1.96 and NetExchange 3.25 from the Software page
  2. In each program, check Help | About shows the new version

How the pieces fit together

  • The meet manager exports its Lynx files (lynx.evt, lynx.sch, lynx.ppl) to a folder on the NetExchange computer
  • NetExchange runs on that computer with its USB key plugged in, and its Event Files and Results Files directories point at that folder: see Connection to FieldLynx
  • FieldLynx connects to NetExchange over the network and loads the schedule
  • After the event, FieldLynx sends the marks back through NetExchange, and the meet manager picks them up (Get Marks in HyTek Meet Manager)
  • FieldLynx never opens lynx.evt or lynx.ppl itself: NetExchange streams the event to it and writes the results as .lff files in the Results Files folder. FieldLynx doesn't use .lif files, which are FinishLynx's results format

Connect FieldLynx to NetExchange

  1. Make sure the FieldLynx device and the NetExchange computer are on the same network
  2. Confirm the IP address of the NetExchange computer
  3. In FieldLynx, go to Options | Preferences, Database tab
    1. Set Serial to Network (connect)
    2. Set the port to the one NetExchange shows (default 1950)
    3. Set the IP address to the NetExchange computer's address
  4. Click OK, then click Load Schedule and pick an event

If Load Schedule still stays on Connecting

  1. Check the NetExchange window for errors in its log
  2. Confirm the FieldLynx device's IP address is on the same subnet as the NetExchange computer
  3. Make sure the NetExchange USB key is plugged in: see License and seats
  4. Check Windows Firewall on both computers. Turn it off for each connection type, or allow FieldLynx and NetExchange through it
    1. Antivirus software that controls the firewall can block the connection too

One laptop, or no network at all

  1. Current FieldLynx versions can't read event files from a folder: the Database tab offers only None and Network
  2. Install and run NetExchange, with its USB key, on the FieldLynx computer itself, and point its Event Files and Results Files directories at the folder with lynx.evt and lynx.ppl
  3. In FieldLynx, set the Database tab IP address to that same computer and the port to the one NetExchange shows
    1. NetExchange then streams the events to FieldLynx and writes the .lff results on that computer, with no network needed, even when the meet manager isn't on site

Working offline at the field

  1. Connect on the wired network first and click Load Schedule so the events and athletes are on the FieldLynx laptop
  2. Take the laptop to the ring or pit and run the event with no network
  3. Back in range with NetExchange running, click Send results to database in FieldLynx, then Get Marks in the meet manager
    1. An access point on the timing network also lets the field laptops stay connected without affecting FinishLynx

The FieldLynx quick start guide covers the Database tab and firewall settings, and the sample data import video shows the meet manager, NetExchange and FieldLynx working together. Sample files and file specifications come from Lynx.

Good to know

Full FieldLynx can't load entries without NetExchange. FieldLynx Lite is different: it reads a lynx.ppl file straight from a folder. See FieldLynx or FieldLynx Lite.

Related resources