Start lists not found
If FinishLynx says "could not find .evt file", or the drop-down is blank after you click Load Schedule, the Input Directory setting or the lynx.evt file itself (which holds all the start lists) is usually the problem. The steps are the same in FinishLynx LITE.
How to fix it
Check the Input Directory and lynx.evt
- Click File | Options | Database tab
- Check that the Input Directory is the folder where the meet software saves lynx.evt
- Open that folder in File Explorer and look for lynx.evt
- Not there: the meet software isn't exporting it. Update the start lists in the meet software
- There but empty when you open it in Notepad: seed the events in the meet software and update the start lists again
- There with start lists in it: if the folder is on another computer, check that the FinishLynx computer can open it over the network
If the event list stays empty
- Click File | Goto Event
- Click Load Schedule, then open the drop-down list. The events only appear after you click Load Schedule
- A lynx.sch file is optional. It only sets the order of events and turns on Schedule Next and Previous; without it, FinishLynx lists the events from lynx.evt
If events load but no athletes appear
- Open lynx.evt from the Input Directory in Notepad
- Check that each event line has its athletes listed on the lines below it
- If an event has none, seed it in your meet software, update the start lists, then load the event again
- With no athletes listed, FinishLynx looks athletes up in lynx.ppl as you type their ID, so typing a bib number can still bring up a name even though the start list is missing
- Check that lynx.ppl (and lynx.sch, if your meet software makes one) is in the same folder
HyTek says "Results file … not found", or the .lif has no event number
- The event was opened as a blank event (File | New) instead of from the schedule, so FinishLynx named the .lif after its own timestamp with no event number, and the meet software can't match it
- In the meet software, update the start lists so it writes lynx.evt, lynx.ppl and lynx.sch
- Check that FinishLynx points at the folder the meet software writes to. Many computers have more than one tfmeets6 (or meet) folder, so check the full path
- Check that Write LIF File is On on the Database tab
- Open the event from File | Goto Event | Load Schedule, time it and save it, then get the times again
- With chips, lynx.ppl links each bib to a name and the chip map file links each chip to a bib, so you don't need to add names to the chip file
Scratch an athlete after the start lists are loaded
- Open the event in FinishLynx
- Right-click the athlete, choose Status, and pick the status (for example Did not start or Scratched)
- Save the event. The status goes to the meet software with the results
Where the files go
- Input Directory (File | Options | Database tab): FinishLynx reads lynx.evt (start lists), lynx.ppl (athletes) and lynx.sch (schedule) from this folder
- Output Directory: FinishLynx writes a .lif results file here each time an event is saved, as long as Write LIF File is On
- Most setups point both at the same folder. Keep that folder on the FinishLynx computer, so a network drop between computers doesn't cut FinishLynx off from its files
- lynx.evt is the only file you must have; without it you can only open blank events. lynx.ppl lets you add an athlete who isn't in the start list by typing their ID, and lynx.sch sets the event order for Schedule Next and Previous
Recommended folder setup
- Create a Meets folder on the C: drive of the FinishLynx computer
- Share it on the network with read and write access, and map it as a network drive on the meet management computer
- In the meet software, set the output (database) directory to that folder
- In FinishLynx, set the Event Directory and Backup Directory (Event | Options) and the Input Directory and Output Directory (File | Options | Database tab) to the same folder
- Start each meet with an empty folder: move the last meet's files into an archive folder first
Setup steps for each program
- HyTek, and the video Tutorial: Integrate FinishLynx with Hy-Tek Meet Manager
- MeetPro
- LynxPad
- Athletic.net RunMeet
- OpenTrack
- The file formats are in Database files in the manual