Flashing screens
Flashing screens happen in the legacy multi-layout setup, where separate Time, Start List and Results layouts are open and a FinishLynx script (ResulTV.lss) switches between them automatically.
The usual cause is two FinishLynx scoreboard outputs both sending switching commands to ResulTV. Each tries to bring its own layout to the front on every update, and with running time updating 10 times per second the layouts fight and appear to flash.
How to fix it
Leave one output in charge of switching
- In FinishLynx, go to Scoreboard | Options and look at every scoreboard that points to ResulTV.
- Decide which one should control the layout switching.
- Move every other ResulTV output to a script that sends data only, without auto-switching commands.
- Confirm only one scoreboard output sends layout-switching commands to ResulTV at a time.
How the automatic switching works, and the layout names it expects (Starts.rtv, Results.rtv, Time.rtv, Message.rtv), is in the manual's Automatic switching of display screens. If the text on the layouts is also garbled or lands in the wrong fields, see Weird characters and letters.