No light, solid red light or stopped after a fall
The red light next to the XLR port blinks when the gauge has power and is working. No light almost always means no power is reaching the gauge, so start with the power path, not the settings. A light that stays solid, or no data after a fall, points to a fault in the gauge or its head.
How to fix it
No light: check the power
- On the camera back, the Wind Gauge Input Cable's red and black leads go in the red and black 12VDC ports.
- On a Connection Box, the red and black plugs go in the 12 V ports, not a photo-eye port.
- Test the 12 V port: measure across the red and black ports with a voltmeter (it should read 12 V), or plug in another 12 V accessory, such as a RadioLynx receiver, and see whether it powers up.
- Bypass the 200 foot XLR cable with a shorter one. If the light comes on, the long cable is likely damaged.
- A gauge on a SeriaLynx needs its own DC power supply; the SeriaLynx doesn't power it.
- The settings and wiring are in Initial connection.
After a fall
- Take the tube off and check that the internal cable is still connected to the wind head.
- If the head is cracked or broken, or the gauge still sends no data, it needs a repair: submit an RMA. See also Physical damage.
Solid red light
- Check the Wind tab in File | Options: Wind Module Lynx, Serial Port
<camera name> (Body)(or<camera name> (C-Box)on a Connection Box), 9600 baud, 8 data bits, no parity, 1 stop bit. - Restart FinishLynx and start a test race. A reading appears after about 10 seconds.
- If you have a second gauge, try it on the same cable and settings. If the second gauge works, the first has an internal fault and needs a repair.
If the light blinks but FinishLynx still shows no reading, see No wind readings in FinishLynx. Still no light with 12 V at the port and a good cable, or a cracked head: send the gauge in.
Send it in for repair
Start an RMA. The portal walks you through what to include and where to ship it.