Error 129
Error 129 ("Failed Contact Address") while a camera boots means FinishLynx can't reach the camera over the network. Most often FinishLynx is using the computer's wireless adapter instead of the wired one, or another device has taken the camera's address.
Before changing settings, look at the lights on the back of the camera: one pattern means a hardware fault that no setting will fix.
How to fix it
Rule out a hardware fault
- Look at the lights. If the Error light is flashing and the WiFi and GPS lights show a mix of red and green, the camera has a hardware fault
- It usually comes from the board inside the front plate, often after a fall that bent the plate
- Try once: remove the 4 screws on the outer corners of the front plate, refit the plate, tighten the screws and boot again
- If the same lights come back, the camera needs a repair: submit an RMA. See also Camera body or ports damaged
- Lights not showing that pattern? Carry on below
Point FinishLynx at the wired adapter
- In File | Options | General tab, set Camera Network to the static address you gave the Ethernet adapter (192.168.0.5 on the standard setup) and click OK
- Close FinishLynx and turn the camera off
- Turn Wi-Fi off: in Settings | Network & internet, turn Wi-Fi Off
- Open FinishLynx and reboot the camera
- Wi-Fi can be used after the cameras have loaded if it's on a different subnet from the camera network. Lynx recommends keeping Wi-Fi off on timing laptops if possible, and doing internet work (live results, meet management) on a separate computer
Check these too
- Another device on the network may be using the camera's address (one above the computer's: 192.168.0.6 on the standard setup). Remove or re-address it so the camera's address is free
- Make sure you are on the latest FinishLynx. Help | About shows your version; the current one is on the Software page
- The BOOT light shows how far the camera got: solid red for more than a minute is a boot failure, flashing amber means it booted and is waiting for FinishLynx, solid green means it is loaded
- Each light has its own page under FinishLynx not finding camera
- Error 201 instead? FinishLynx needs updating: Error 201
- Error 202 is usually fixed by running FinishLynx as administrator: Error 202
- Any other number: Other code
Send it in for repair
Start an RMA. The portal walks you through what to include and where to ship it.