Automatic capture not working

Automatic capture needs three things: the Automatic Capture (ACM) plug-in installed and licensed on this computer, Capture Method set to Automatic for each camera, and capture switched on in the event window.

How to fix it

Install the plug-in (new computer or first setup)

  1. Download the FinishLynx Automatic Capture Plugin from the Plugins section of the Software page
  2. Close FinishLynx, run the installer and enter your Automatic Capture serial number when it asks
    • On the serial sheet it may be labeled "Virtual Photo Beam Unit"
    • Plug-in serials carry over when you install a new FinishLynx version into the same folder; on a new computer, enter it again
  3. Open FinishLynx and check that Help | About lists the Automatic Capture plug-in with its serial number

Set each camera to Automatic

  1. From the Hardware Control window, open Camera Settings and click the Capture tab
  2. Set Capture Method to Automatic
  3. Uncheck Manual
  4. Click OK
  5. Repeat for each camera. Camera settings don't carry over to a new computer, so set them again there

Turn capture on in the event window

  1. Click the capture icon so it shows the enabled state. The icon toggles between disabled and enabled
    • Alt-T also toggles capture

Check these

The Automatic Capture page of the Online Manual covers the detection settings (Object Threshold, active area, Min Time), and the ACM plug-in video shows the setup.