Which Daktronics setup do I have
Daktronics boards connect to FinishLynx in a few different ways, and what HyTek does depends on the board. Find the setup that looks like yours, then follow its page or the settings under it.
How to fix it
Which setup is yours?
- Football or track scoreboard with an All Sport 5000 console: FinishLynx sends the running clock and results to the console over a serial cable. See LED scoreboard (All Sport 5000)
- Track scoreboard with 6, 8 or 10 lines of lanes and times: FinishLynx sends the running time and lane results over a serial cable, through a Daktronics signal converter
- Script Omni1000placeNEW.lss, Code Set Single Byte, Baud 9600, Data Bits 7, Parity Even, Stop Bits 2.0, Running Time Normal, Results Auto with Always send place, Paging on with Size = the lanes the board shows
- Small portable timer in the infield (TI-2020, TI-2021 or TR-3101): running time only, from FinishLynx over a serial cable through a signal converter
- Script DakMDP.lss, Code Set Single Byte, Baud 19200, Data Bits 8, Parity None, Stop Bits 1.0, Running Time Normal, Results Auto with Always send place, Paging on, Size 1, Time 5.0. The serial port can be the computer's or the Connection Box's (Camera 1 (C-Box))
- LED video display (video board): FinishLynx sends running time and results over the network. See LED video displays
- LED message display (Galaxy or M3): FinishLynx sends running time and results over the network with one Dak-Extended.lss entry on Network (UDP), port 3002. The settings are on the same page
- OmniSport 2000 console with track push buttons: Daktronics' own timing console runs the board. FinishLynx isn't part of this setup
Where HyTek fits
- HyTek Meet Manager can't send data to a football or track scoreboard. On those boards, the clock and results come from FinishLynx (or the OmniSport console)
- On a video display or message display, HyTek can also send start lists, results and team scores to the board, with its optional Alpha Scoreboard Interface (bought from HyTek)
- HyTek connects to the FinishLynx computer over the network, through a shared folder: see HyTek
Every setup above, with its wiring drawings, is in Daktronics' Track & Field Interfaces for Scoreboards & Displays setup guide.