Source is set up but nothing shows

When the connection is good but the display stays empty, the usual causes are a source that has not been reloaded, a source script that does not match the program sending the data, or FinishLynx set to send results only on request. Work through the checks below in order.

How to fix it

Check the ResulTV side

  1. In ResulTV go to File | Options | Sources tab. A new or changed source shows Not Loaded until you close and reopen ResulTV. Restart it and check the status reads Running.
  2. Check the source Script matches what is sending:
    • FinishLynx using ResulTV.lss: FinishLynx.rss
    • FinishLynx, FieldLynx or LynxPad using a ResulTV_Video script: VideoDisplay.rss
    • Hy-Tek Meet Manager for Track and Field: Hytek.rss
    • Hy-Tek Meet Manager for Swimming: HytekSwim.rss
    • MeetPro Meet Manager: MeetPro.rss
  3. Check the green USB dongle is plugged in. Without it, ResulTV runs in demo mode and does not receive data from outside sources. See License, dongle and serial number.
  4. For a Video Display layout, the object must have Type: Dynamic and Field: Video Display Data (double-click the object, Basic tab).

Check the FinishLynx side

  1. Go to Scoreboard | Options and check the scoreboard status reads Running. If not, make sure something is selected next to Serial Port, click OK and restart FinishLynx.
    • Running only means FinishLynx is sending. It shows Running even when nothing receives the data, so check the status on the ResulTV Sources tab as well.
  2. Under Results, choose Auto to send the start list and results as soon as you open or evaluate an event. If Results is set to Manual, nothing is sent until you click Scoreboard | Refresh.
  3. Under Running Time, choose Normal to send the clock.
    • To show the start list once the event is open, before the start and the results, expand the Running Time options and check Send results if armed. Leave it unchecked on a running-time board, so that board shows 0:00 when the event is armed.
  4. Results are sent only after the running time has stopped. Stop the clock with Scoreboard | Stop (Alt+S) or a photo-eye, then evaluate.

If the source is serial or Hy-Tek

  • A serial source needs a DB9 null modem cable between the two COM ports, and one free COM port on the ResulTV computer for every serial source. Add a USB to serial adapter if you run out of ports, or move the sources to the network.
  • FinishLynx serial settings stay at their defaults: 9600, 8, None, 1.
  • Hy-Tek Meet Manager sends nothing on its own: press Ctrl+F10 to send a start list and Ctrl+F11 to send results. In Meet Manager for Track and Field, Ctrl+F12 sends an event's combined results once all heats are done.

Connection settings (Network (listen), port, IP address, firewall) are covered in FinishLynx connection. Garbled text or data in the wrong fields is covered in Weird characters and letters.

Creating and deleting sources is in the manual's Data source basics.