Reaction times cluster at one value
This is the Active Time window, not a sensor fault. ReacTime only counts movement inside that window, so an athlete who moves before the window opens is reported at its edge. With Active Time at -0.3 From Gun, every early false start reads around -0.298 to -0.300.
How to fix it
Widen the detection window
- On the Command Center, press Menu and go to the Detection menu, then Active Time
- Read the value. -0.3 From Gun means movement earlier than 0.3 seconds before the gun is ignored
- Use the up and down arrows to set a wider window
- The range is -2.0 seconds before the gun to 2.0 seconds after Set. The Command Center reference page gives -0.6 From Gun as the default
- While you are in the Detection menu, check Threshold: Normal for most athletes, Aggressive for lightweight athletes
- Run a test start where someone deliberately leaves early and confirm the reported time now varies
The setting is described in the Command Center reference and the Block Sensor Menu Reference; the defaults are listed under Configure the Command Center, and the setup is in the ReacTime Championship Setup QSG.
Good to know
There is no published pressure value that triggers the sensor. The system is certified to World Athletics standards. A setting with a positive value, such as 0.3 From Set, ignores movement in the first 0.3 seconds after the Set command instead.
Related resources
- ReacTime Championship Setup QSG — Guide · PDF