How meet software shares files with FinishLynx

Every meet program (LynxPad, HyTek Meet Manager, MeetPro, Athletic.net RunMeet through AthleticLOCAL, OpenTrack) connects to FinishLynx the same way: through files in one shared folder. The meet software writes the start lists there, FinishLynx reads them and writes a results file for each race back into the folder.

One computer can run both programs, but Lynx support recommends a second computer for meet management on meet day. No extra Lynx plug-in or license is needed for any of them.

How to fix it

Set up the shared folder (recommended layout)

  1. On the FinishLynx computer, create a folder named Meets on the C: drive. Keeping it on the FinishLynx computer means a network drop doesn't stop timing.
  2. Share the folder with read/write access, and map it as a network drive on the meet software computer. See Multi-computer networking and the Windows 11 networking guide.
  3. In the meet software, set its database or output folder to Meets. After you seed and update start lists, lynx.evt, lynx.ppl and lynx.sch appear there.
  4. In FinishLynx, go to File | Options, click the Database tab and set the Input Directory and Output Directory to Meets, then set the Event Directory and Backup Directory to the same folder.
  5. Run a test race: seed and update start lists in the meet software, load the schedule in FinishLynx, time and save the race, then pull the results into the meet software.

Setup steps for each program

The files

  • lynx.evt: every seeded event, heat and athlete with lane. It is the only file FinishLynx needs to open events with names already filled in. Without it you can only open blank events.
  • lynx.ppl: everyone in the meet database, so you can add an athlete who isn't in the start list by typing their ID (bib) number.
  • lynx.sch: the order of events, so FinishLynx can step to the next event. It is optional.
  • .lif: the results file FinishLynx writes when you save an event, named event-round-heat (for example 003-4-01.lif). It is plain comma-separated text, and the meet software reads the times from it.
  • .evn: the race and image file FinishLynx saves for every race. It is not a results file.

The file formats are in the manual under Database Files.

Fixing a race after results were pulled

  1. Correct the race in FinishLynx and save it again. This rewrites the .lif file.
    • The meet manager can do this on another networked laptop running FinishLynx as an evaluate computer: Hardware Type set to None, with C:\Lynx\Temp shared on the capture computer so it can see the race images. See Capture-and-read FinishLynx setup.
  2. Pull the results for that event into the meet software again.

Between meets

  1. After each meet, copy everything from Meets into a Meets Archive folder (one subfolder per meet).
  2. Empty Meets before the next meet, so new events don't overwrite or mix with old event files.

If you have no meet management software

  • Lynx packages include LynxPad, a basic meet manager. Its serial number is on the flash drive that ships with the package.
  • Without a serial, LynxPad runs in demo mode: everything works except printing reports. You can enter the serial later without reinstalling.
  • HyTek Meet Manager, MeetPro and Athletic.net RunMeet all work with FinishLynx if you prefer a third-party meet manager.

Export formats and live results

The meet software scores the events and exports CSV, Excel, PDF or HTML. For real-time results, an API question, or sample files for your own system, see Results export and live data.